Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Certification: CE, ISO13485
Still deciding? Get samples of US$ 450/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 13485, FSC
Export Year
2010-11-01
  • Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor
  • Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor
  • Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor
  • Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor
  • Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor
  • Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor
Find Similar Products

Basic Info.

Model NO.
MO-002
Group
Patient/Doctor
OEM
Available
Warranty
1 Year
Location
From Guangzhou Airport 1.5 Hour
Certificate
ISO13485, ISO9001, Ce, BV
Weight
12kg
Size
15 Inch
Transport Package
2PC/CTN
Specification
46*39*45cm
Trademark
MEDCO
Origin
Guangdong China
HS Code
9018193010
Production Capacity
50000 Pieces/Month

Product Description

Product Description                                                                                                                               
Item No. MO-002
Size 46*39*45cm
Monitor 15 inch
Standard parameters 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
G.W. 12KG
Warranty 1 year
Trade Mark MEDCO
After-Sale Service Onsite Training
Transport Package Aluminum-Plastic Box + Carton
MO-002 Multi-parameter Patient monitor
Ce ISO 15′′ Multi-Parameter Diagnostic ICU Portable Patient Monitor




Features &Benefits:
  1. 15" color TFT display, high resolution: 1024×768dpi;
  2. Separated para board: ECG, NIBP, SpO2 board;
  3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
  4. Real time S-T segment analysis, and ARR analysis;
  5. SpO2 Pitch Tone Variation and Drug Dose Calculation;
  6. Parameter waveform and characters color selectable
  7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  8. Standby mode for Energy saving and suspend monitoring;
  9. 7-lead ECG waveforms display in phase;
  10. Capture dynamic waveforms;
  11. Built-in rechargeable lithium battery, and battery volume checking,
  12. AC power checking
  13. Efficient resistance to interference of defibrillator and HF knife;
  14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
  15. Networking capacity and TCP/IP networking platform enable abundant future upgrade
  16. Time delay switch-off function keep the monitor data restart monitor;
  17. Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,




Performance Specifications
Display:       15"color TFT
Rolling and refreshing waveform display
Resolution: 1024×768
Multi display selectable including:
Large-font display
Trend coexist display
OxyCRG dynamic view display.
Bed-to-bed view display
Trace: 9 waveforms(7 ECG, 1 SPO2 and 1 RESP)
Sweep speed:12.5mm/s,25mm/s,50mm/s
Indicator: Power/battery indicator light
QRS beep and alarm sound
Battery:Rechargeable lead acid cell, 12v/4AH
Max.24 hour for charging, 4 hours for continue working
Trend:Parameter graphic and tabular trends:
5s/piece,8 hours;
1min/piece,168 hours(24hour×7days)
5min/piece,1000 hours.
Storage: NIBP: 1000 groups
Alarm: 200 groups
Full disclosure waveforms: 3600S
SD card external storage
Alarm:User-adjustable High, Medium and Low limits 3-level
 Audible and visual alarm
Networking: Connected to central monitoring system
TCP/IP netting platform
Recorder:Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined 
Recording width: 50mm
Printing speed: 50mm/s
Recording type:Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record



Standard parameter:

ECG:

Lead mode: 5 -lead(R,L,F,N,C)
Lead selection : I,II,III,avR,avL,avF,V
Waveform:     3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 12.5mm/s;25mm/s;50mm/s
Heart rate range:    Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichecer is greater
Resolution:     1bpm
Filter: surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%
Protection:       withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detecton: 
Measurement range:    2.0mV~+2.0mV                         
 Alarm Range:          -2.0mV~ +2.0mV
Accuracy:              -0.8mV ~+0.8Mv
Error:                 +0.02Mv
Arrhythmia analysis:    YES


SPO2
Measurement range:        0~100%
Resolution:                1%
Accuracy:                 +2%(70-100%);0-69% unspecified
Alarm range               0~100%
Pluse Rate:                
range:                 20~300bpm
Resolution:             1bpm
Error:                 +1bpm or +2%,whichever is greater


NIBP
Method:                   Digital Automatic oscillometric
Operation mode :            Manual/Automatic/continuous
Auto measurement time:      Adjustable(1~480min)
Measurement Unit:          mmHg/Kpa selectable
Measurement types:         Systolic, Diastolic, Mean  
Measurement tange:
Range of Systolic pressure:    Adult: 40~270mmHg
Pediatric: 40~220mmHg
Neonate: 40~135mmHg
Range of mean pressure:      Adult: 20~235mmHg
Pediatric: 20~165mmHg
Neonate: 20~110mmHg
Range of diastolic pressure:   Adult: 10~215mmHg
Pediatric: 10~150mmHg
Neonate :10~100mmHg
Over-pressure protection:Double safety protection
Resolution:1 mmHg
Alarm:Systolic.Diastolic,Mean



RESPIRATION
Method:Thoracic impedance
Measurement range: Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm: YES,10~40s
Resolution:1rpm
Accuracy:+2rpm



TEMPERATURE
Compatible probe:YSI or CYF
Measurement range: 5~50ºC
Resolution :0.1ºC
Accuracy:+0.1ºC
Refreshing time: about 1
Average measuring time: <10s


FHR
Transducer:   Multi-crystal, Pulsed Doppler
Measurement range:  50~210 BPM
Working frequency:   1 MHz
Strength:   <5mW/cm2
Signal processing:  
special DSP system and modern recognization.
Resolution:   1BPM
Accuracy:    ±1BPM 
Alarm Range:  High: 160,170,180,190 BPM, 
Low: 100,110,120 BPM


FM
Manual button marking,
automatic FM identifying function


TOCO Measuring
Transducer:  External pressure transducer
Measurement range:  0~100 units
Resolution:  1rpm
Accuracy:  ±2 rpm



IBP
Channel: 2 channels
Range: -50-300mmHg
Resolution: 1mmHg
Accuracy: ±4mmHg(±4%)
Unit: mmHg, Kpa
Converter Sensitivity: 5mV/V/mmHg
Transducer sites: ART/PA/CVP/LAP/RAP/ICP


EtCO2( Sidertream CO2)
Measurement range:   0~99mmHg
Accuracy:   +2mmHg (0~40mmHg)
Sampling Range:   100ml/min
Sampling rate accuracy:   15%
Respiration rate:   0~120rmp
Respiration accuracy:  +2rmp (0~70rmp)
+5rmp (>70rmp)
Respiration time:   <240msec (10% to 90%)
Delay time:  <2s


EtCO2 (mainstreaam CO2)
Method:   Infrared Spectrum
Range:   0.0-10% (0~76%)
Resolution:   1mmHg (0.1%)
Accuracy:   <5%(±4.0 mmHg)
         Or<10%(of Readings)


Recorder:     
Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined 
Recording width: 50mm
Printing speed: 50mm/s
Recording type:  Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record



Miscellaneous
Satety:              
Safety level: Class I, type CF
Dimendion and Weight
Dimendion:      28*42*48cm         
G.Weight:        <6.5KS


Operation Environment
Temperature:Working 0~+40ºC
Transportation and storage -20~+60ºC
Humidity:working≤85%
Transportation and storage≤93%
Power:AC 100-240,50/60Hz
Patient range:  Neonate,pediatric,and adult patients



Accessories supplies
(1) 5 lead ECG cable  
(2) 1 spo2 probes  
(3) 1 NIBP prbe  
(4) 1 temp probe
(5)1 ground connecting liner  
(6) Chest electrode (10pcs/set)