Customization: | Available |
---|---|
Customized: | Non-Customized |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Color Doppler Ultrasonic Diagnostic Ultrasound Screen Trolley Technical Parameters |
1: | Summary of main specifications and system of cart type color Doppler ultrasound | ||
1.1 | Trolley type full digital color Doppler ultrasonic mainframe | ||
1.2 | Ultrasonic host operating system: Windows operating system | ||
1.3 | Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
||
1.4 | Probes: Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
||
1.5 | Applications and report: Support abdomen, obstetrics, gynecology, heart, urology, small organs, superficial, blood vessels, pediatrics, etc. advanced measurement software package, report software package, patient management software package |
||
☆1.6 | carotid artery intima measurement thickness(IMT) | ||
☆1.7 | Automatic spectral envelope measurement | ||
1.8 | Full digital transmission and reception of beam synthesizer | ||
1.9 | Color Doppler imaging(C) | ||
1.10 | Pulse Doppler Imaging(PW) | ||
☆1.12 | Coherent Contrast imaging(CCI) | ||
1.12 | Continuous wave Doppler imaging(CW) | ||
☆1.13 | B/C/D Real-time three synchronous imaging | ||
☆1.14 | Power Doppler imaging(PDI) | ||
☆1.15 | Direct power Doppler imaging(DPDI) | ||
1.16 | M mode imaging | ||
☆1.17 | Anatomic M mode imaging | ||
☆1.18 | Color Doppler M mode imaging | ||
☆1.19 | Elastography | ||
☆1.20 | Tissue Doppler imaging(TDI) | ||
☆1.21 | Strain rate imaging (SRI) | ||
1.22 | Tissue harmonic imaging(THI) | ||
1.23 | Fusion harmonic imaging(FHI) | ||
1.24 | Speckle Reduce imaging(SRI) | ||
☆1.25 | Panoramic imaging | ||
☆1.26 | Deflection imaging | ||
☆1.27 | Trapezoidal imaging | ||
1.28 | Adaptive velocity optimization | ||
☆1.29 | Free hand 3D | ||
1.30 | Real time 3D imaging(3D/4D) | ||
1.31 | DICOM3.0 | ||
1.32 | Monitor:≥21.5 inch,high definition ultrasonic display | ||
1.33 | ≥10.4 inch touch screen | ||
1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. | ||
1.35 | The system has the function of on-the-spot upgrade | ||
1.36 | Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. | ||
1.37 | Probe interface: 4 | ||
1.38 | Chinese and English System, Chinese and English input, optional | ||
1.39 | Depth:≥360mm; | ||
1.40 | Extended imaging | ||
2: | Probes | ||
2.1 Convex probe |
Fundamental Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz, Harmonic Frequency: 4.0MHz/4.6MHz/5.0MHz, |
||
2.2 Linear probe |
Fundamental Frequency:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz, Harmonic Frequency: 8.0MHz/9.2MHz/10.0MHz, |
||
2.3 Trans-vaginal probe |
Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
||
2.4 Micro-convex probe |
Fundamental Frequency: 3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz, Harmonic Frequency: 6.0MHz/7.0MHz/8.0MHz, |
||
2.5 Cardiac probe |
Fundamental Frequency:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz, Harmonic Frequency: 3.4MHz/3.8MHz/4.2MHz, |
||
2.6 4D Volume probe |
Fundamental Frequency: 2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz, Harmonic Frequency: 4.0MHz/5.0MHz/6.0MHz, |
||
3: | 2D imaging mode | ||
3.1 | Gain:0-100,Step 2 adjustable | ||
3.2 | TGC:8 segment adjustable | ||
3.3 | Maximum focus point:≥7, which can be moved throughout the whole process. | ||
3.4 | Speckle reduction:0-5,5 level | ||
3.5 | Space Synthesis:0-2,2 level(Liner probe: 3 level, cardiac probe:0) | ||
3.6 | Dynamic:30-180,35 level,step 5 adjustable | ||
3.7 | Line density:low,middle,high,3 level | ||
3.8 | Frame correlation:0-4,4 level | ||
3.9 | Noise reduction:0-5,5 level | ||
3.10 | Edge Enhancement:0-5,5 level | ||
3.11 | Sound power:2-10, 9 level | ||
3.12 | Grey scale:0-67, 67 level | ||
3.13 | False color:0-67,67 level | ||
3.14 | Image style:Soft-Comparison,2 level | ||
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |||
4: | Color Doppler imaging mode | ||
4.1 | Blood gain:0-100,Step 2 | ||
4.2 | Parameter display:Velocity,Variance | ||
4.3 | B-Restrain(B/W restrain):0-7, 7 level | ||
4.4 | Speed Through:0-8, 8 level | ||
4.5 | Sampling number:6-24, 7 level | ||
4.6 | Blood flow preferred:0-8, 8 level | ||
4.7 | Filtering:1-6, 6 level | ||
4.8 | Sound power:2-6, 4 level | ||
4.9 | Noise reduction:0-4, 4 level | ||
4.10 | Smooth treatment:0-4, 4 level | ||
4.11 | Frame correlation:0-6, 6 level | ||
4.12 | Chromatography(Blood flow graph):0-37, 37 level | ||
4.13 | Line density:Low-Middle-High, 3 level | ||
4.14 | Frequency:4 level adjustable | ||
4.15 | Velocity:Minimum 0.4K,Maximum 40.5K Convex probe:0.4K-4.3K-38.5K Linear probe:0.4K-14.7K-39.0K Trans-vaginal probe:0.4K-7.8K-39.7K Volume probe:0.4K-4.2K-34.8K Micro-convex probe:0.4K-10.3K-40.5K cardiac probe:0.4K-7.8K-39.7K |
||
PS:The frequency of the probe changes and the frequency value changes | |||
PS:Frame rate changes with speed | |||
5: | Pulse wave Doppler(PW) | ||
1 | Gain:0-100,Step 2 | ||
5.2 | Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close | ||
5.3 | Sample volume:0.5mm~30mm | ||
5.4 | Blood angel:-75-75 degree,Step 5 | ||
5.5 | False color:0-67, 67 level | ||
5.6 | Dynamic range:20-40, 4 level | ||
5.7 | Filter:0-9, 9 level | ||
5.8 | Smooth treatment:1-4, 4 level | ||
5.9 | Sound power:2-5, 4 level | ||
5.10 | Volume:0-100, 10 level,Step 10 | ||
5.11 | Audio filtering:0-4, 4 level | ||
5.12 | Base line:-1.0~1.0, | ||
5.13 | Grey map:0-67, 67 level | ||
5.14 | Scan velocity:100-500, 6 level | ||
5.15 | PRF:Minimum 0.5K,Maximum 87.5K Convex probe:0.5K-4.3K-63.3K Linear probe:0.5K-14.5K-78.4K Trans-vaginal probe:0.5K-8.1K-78.4K Volume probe:0.5K-4.2K-53.8K Micro-convex probe:0.5K-10.3K-81.1K cardiac probe:0.5K-4.3K-87.5K |
||
5.16 | Frequency:4 level | ||
PS:The frequency of the probe changes and the PRF value changes | |||
PS:The frequency of the probe changes and the frequency value changes | |||
6: | Continuous Wave Doppler(CW) | ||
6.1 | Support probe:Cardiac probe | ||
6.2 | Adjustment of B mode parameters is switchable | ||
6.3 | Gain:0-100,Step 2 | ||
6.4 | Sampling line position is adjustable | ||
6.5 | PRF:0.9K~36.1K | ||
6.6 | Baseline:-1.0~1.0 | ||
6.7 | Blood angel:-75~75 degree | ||
6.8 | Grey map:0-67 | ||
6.9 | Scan velocity:100-300 | ||
6.10 | False color:0-67 | ||
6.11 | Dynamic range:20-40 | ||
6.12 | Filtering:0-9,9 level | ||
6.13 | Smooth treatment:1-4 | ||
6.14 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz,4 level adjustable | ||
6.15 | Sound power:2-5 | ||
6.16 | Volume:0-100 | ||
6.17 | Audio Filtering:0-4 | ||
☆7: | Anatomical M imaging | ||
7.1 | Support probe:Convex probe, Linear probe,Cardiac probe | ||
7.2 | Adjustment of B mode parameters is switchable | ||
7.3 | Gain:0-100,Step 2 | ||
7.4 | M Sampling line angel is adjustable | ||
7.5 | M Sampling line length is adjustable | ||
7.6 | Sampling line:3,Can be displayed or hidden separately | ||
☆8: | Blood flow M model(MC) | ||
8.1 | Adjustment of B mode parameters is switchable | ||
8.2 | Gain:0-100,Step2 | ||
8.3 | MC Sampling line angel is adjustable | ||
8.4 | MC Sampling line length is adjustable | ||
8.5 | Frequency:4 level | ||
8.6 | Sampling number:6-24 | ||
8.7 | Speed through:0-8, 8 level | ||
8.8 | Scan velocity:150-500 | ||
8.9 | Frame correlation:0-6, 6 level | ||
8.10 | Filtering:1-6,6 level | ||
8.11 | Blood flow preferred:0-8,8 level | ||
8.12 | Smooth treatment:0-4,4 level | ||
8.13 | Map:0-37, 37 level | ||
☆9: | Elastography | ||
9.1 | Adjustment of B mode parameters is switchable | ||
9.2 | Gain:0-100,Step 2 | ||
9.3 | B/E,Double real-time display on the same screen | ||
9.4 | Probe displacement curve display:Up/Down | ||
9.5 | Pressure indicator bar display | ||
9.6 | Frequency:8-9 level,Adjustable;According to the probe display | ||
9.7 | Noise reduction:0-2, 2 level | ||
9.8 | Frame correlation:0-3, 3 level | ||
9.9 | Comparison:0-13, 13 level | ||
9.10 | False color:0-3, 3 level | ||
9.11 | Don't support cardiac probe | ||
☆10: | Tissue Doppler imaging(TDI) | ||
10.1 | Support probe: Cardiac probe | ||
10.2 | Adjustment of B mode parameters is switchable | ||
10.3 | Gain:0-100,step 2 | ||
10.4 | ROI area adjustable | ||
10.5 | Sampling number:6-24 | ||
10.6 | Velocity:0.4K-8.0K | ||
10.7 | Frame correlation:0-6,6 levels | ||
10.8 | Tissue preferred:0-7, 7 level | ||
10.9 | Frequency:2.0MHz/2.3MHz/2.5MHz/3.0MHz | ||
10.10 | Support color reversal | ||
☆11: | Strain rate imaging | ||
11.1 | Support probe: Cardiac probe | ||
11.2 | Adjustment of B mode parameters is switchable | ||
11.3 | ROI area adjustable | ||
11.4 | Gain:0-100,Step 2 | ||
11.5 | Sampling number:6-24,6 level | ||
11.6 | Axial average:1-4, 4 level | ||
11.7 | Velocity:0.4K-8K | ||
11.8 | Frame correlation:0-6, 6 level | ||
11.9 | Tissue optimization:0-7,7 level | ||
☆12: | Panoramic imaging | ||
12.1 | Support probe:Linear probe | ||
12.2 | Speckle Reduction:0-5, 5 level | ||
☆13: | Deflection imaging | ||
13.1 | Support probe:Linear probe | ||
13.2 | Adjustment of B mode parameters is switchable | ||
13.3 | Deflection angel:8 level | ||
13.4 | Speckle reduction:0-5, 5 level | ||
13.5 | Dynamic rate:30-180,Step 5 | ||
13.6 | Line density:low-middle-high,3 level | ||
13.7 | Frame Correlation:0-4, 4 level | ||
13.8 | False color:0-67, 67 level | ||
13.9 | Image style:Soft-Comparison,2 level | ||
13.10 | Noise reduction:0-5, 5 level | ||
13.11 | Edge Enhancement:0-5,5 level | ||
13.12 | Sound power:2-10,8 level | ||
13.13 | Grey map:0-67,67 level | ||
☆14: | Trapezoidal imaging | ||
14.1 | Probe support:linear probe | ||
14.2 | Adjustment of B mode parameters is switchable | ||
14.3 | Deflection angel:8 level | ||
14.4 | Speckle reduction:0-5, 5 level | ||
14.5 | Dynamic rate:30-180,Step 5 | ||
14.6 | Line density:low-middle-high,3 level | ||
14.7 | Frame Correlation:0-4, 4 level | ||
14.8 | False color:0-67, 67 level | ||
14.9 | Image style:Soft-Comparison,2 level | ||
14.10 | Noise reduction:0-5, 5 level | ||
14.11 | Edge Enhancement:0-5,5 level | ||
14.12 | Sound power:2-10,8 level | ||
14.13 | Grey map:0-67, 67 level | ||
14.14 | Space Synthesis:0-2, 2 level | ||
☆15 | Freehand 3D imaging | ||
15.1 | Support probe:convex probe, linear probe | ||
15.2 | Display model: 4 pictures | ||
15.3 | Image Rotation X/Y/Z Axis | ||
15.4 | Multi-slice Visibility | ||
16 | Real-time 4D imaging | ||
16.1 | Support probe: 4D volume probe | ||
16.2 | Adjustment of B mode parameters is switchable | ||
16.3 | Gain:0-100,Step 2 | ||
16.4 | Display model:one image,two images,four images | ||
16.5 | Image Rotation:X/Y/Z Axis | ||
16.6 | Multi-slice Visibility | ||
16.7 | Light&Shade inversion | ||
16.8 | Smooth:0-4, 4 level | ||
16.9 | Threshold level:0-129, Step 3 | ||
16.10 | Transparency:1-509,Step 10 | ||
16.11 | Render type:4 kinds,Surface,maximum,minimum,perspective | ||
17: | Extended Imaging | ||
17.1 | Gain:0-100,Step 2 | ||
17.2 | TGC:8 segment adjustable | ||
17.3 | Maximum focus point:≥7, which can be moved throughout the whole process. | ||
17.4 | Speckle reduction:0-5,5 level | ||
17.5 | Space Compound:0-2,2 level(Linear probe: 3 level,don't support cardiac probe) | ||
17.6 | Dynamic range:30-180,35 level,Step 5 | ||
17.7 | Line density:Low,Middle,High,3 level | ||
17.8 | Frame correlation:0-4,4 level | ||
17.9 | Noise reduction:0-5,5 level | ||
17.10 | Edge enhancement:0-5,5 level | ||
17.11 | Sound power:2-10, 9 level | ||
17.12 | Grey map:0-67, 67 level | ||
17.13 | False color:0-67,67 level | ||
17.14 | Image style:Soft-Comparison,2 level | ||
17.15 | Extended level: Maximum 72 level Convex probe:9 level Trans-vaginal probe:72 level Micro-convex probe:29 level Cardiac probe:40 level 4D Volume probe:17 level |
||
PS:The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |||
PS: When the probe scan range reaches the maximum, the space synthesized is 0. | |||
18: | Measurement and analysis function: | ||
18.1 | General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle | ||
18.2 | Cardiac:Automatic spectrum envelope,LV,Main Pulmonary artery diameter,RVEDd,RVEDs,LVM,LAV,HR,MVF,AO,AR,LVOT,TVF,Pulmonic valve,Pulmonary vein,RV,Doppler fetal heart sound,LVET,LVM,LVMI,AV | ||
18.3 | Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall) | ||
18.4 | OB:Fetal routine,AFI,TW,GS,CRl,OFD,HL,ulna,NT,Fibula,Nbonel,Radial,Tibia | ||
18.5 | GYN:uterus,cervix,corpus uteri/cervix uterus,left ovarian vein,right ovarian vein,dominant follicle,intima thickness | ||
18.6 | Urology: prostate,residual urine,left kidney,right kidney,left suprarenal vein,right suprarenal,left testis,right testis,left seminal vesicle,right seminal vesicle | ||
18.7 | Abdomen:liver,CHD,partal vein diameter,cholecyst,pancreas,spleen,Internal diameter of abdominal aorta,kidney | ||
18.8 | Small parts:Thyroid | ||
18.9 | Software package:Measurement package,Software package,Medical records management software package | ||
19: | Graphic and text management system | ||
19.1 | Host build in 2 hard disk(SSD 120+1T),Start fast and stable | ||
19.2 | Movie playback:≥1200 frames | ||
19.3 | Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on. | ||
19.4 | Type of report is 16 | ||
19.5 | One key fast report graphic and text management | ||
20: | Interface | ||
20.1 | USB interface: 4 | ||
20.2 | HDMI interface: 1 | ||
20.3 | RJ-45 interface:1 | ||
20.4 | Grounding wire interface:1 | ||
20.5 | DVD RW:1 | ||
21: | Configuration | ||
21.1 | Trolley type full digital color Doppler ultrasound diagnostic system | ||
21.2 | Probe: convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional) | ||
21.3 | ≥13 quick adjusting knobs | ||
22: | Technology, after-sales service and other requirements | ||
22.1 | After acceptance, the warranty is free for two years(Provide manufacturer warranty certificate) | ||
22.2 | Manufacturer has ISO13485 certification and EU CE certification. | ||